Multi-Surface Rewind+ - Low/ No suction

This article contains all the steps necessary to fix suction issues with your Vacuum

UD76800_MSRewind_Launch_HPBanner_Desktop

TIP: If you are experiencing lower suction or if your vacuum is hard to push, try adjusting the nozzle height to the proper setting for your floor type.Nozzle height

Follow these steps if you're experiencing low/ no suction:

  1. Let's start by making sure your dirt cup is properly seated in the unit and there are no gaps. 
  2. Empty your dirt cup by pressing the release button on the lid and rocking the cup out of the unit, then unlock the latch at the bottom to empty the tank.
    DC1-Jun-11-2024-02-10-47-3465-PMDC2-Jun-11-2024-02-10-54-3537-PM
  3. After emptying the dirt cup, remove the lid and the cyclonic filter (black filter basket inside the tank) and clean out any debris and dust. Once it's clean replace the filter by lining up the notches with the dirt cup.
  4. Once you have removed and emptied the dirt cup, you should remove the rinsable filter located underneath the tank's lid. You can remove the filter by twisting open the lid and unlocking the filter.
  5. If you are currently cleaning, tap your filter until clean then replace it in the unit, otherwise rinse the filter under water until it's clear and squeeze it to remove excess water. Allow 24 hours to dry then replace it in the unit.
    Rinsible filter 1Rinsible Filter 2Rinsible filter 3
    Turbo Tool
  6. Lastly, check your hose airpath and turbo tool for any clogs. Make sure your vacuum is upright and press the hose release button, inspect your hose and clear out any clogs, then replace it back in the unit. 
    It is recommended to check the connection point to your dirt cup as well and your brush roll suction port.

    Hanlde1Handle2

CAUTION: Do not replace any of the filters if they are damp.